Validity of Shock Index, Modified Shock Index, Central Venous Pressure and Inferior Vena Cava Collapsibility Index in Evaluation of Intravascular Volume among Hypovolemic Egyptians Patients.

Authors

  • Adel Hamed Elbaih Department of Emergency Medicine, Faculty of Medicine, Suez Canal University, Ismailia, Egypt Author
  • Ahmed Mohamed Housseini Department of Radiology, Faculty of Medicine, Suez Canal University, Ismailia, Egypt Author

Keywords:

Caval index; Clinical predictors; Hypovolemia

Abstract

Background: Assessment of intravascular volume is an important component in care of hypovolemia. Physical examination is inaccurate tools in the assessment of intravascular volume, leading to the need for more objective method and accuracy tool.

Aims: The prediction of validation of shock index (SI), modified SI (MSI), central venous pressure (CVP), and inferior vena cava collapsibility index (IVC-CI) in assessment of intravascular volume.

Methods: This study was conducted as cross-sectional, observational study on 150 Egyptians patients attending to the emergency room with hypovolemia state (systolic blood pressure < 90 mmHg, heart rate > 100 beat/minutes, and capillary refill > 2 seconds, and clinical signs with symptoms suggestive any types of shocks) and all patients enter resuscitation room once they arrive to emergency room (ER). With applied resuscitation guideline methods, all the life-threatening conditions of all participants can be treated.

Results: The studied patients revealed negative correlation between the CVP value and (SI and MSI), but positive correlation with IVC-CI value. In addition, the mean CVP was 3.2 ± 2.2 but the mean  IVC-CI was 74.9% ± 10.5%. MSI has 100% sensitivity and 98% specificity, CVP has 100% sensitivity and specificity, and IVC-CI has 100% sensitivity and specificity in diagnosis of hypovolemia when > 1.3, ≤ 8 cmH2 O, and ≥ 50%, respectively.

Conclusions: Assessment of intravascular volume is an important diagnostic tools and management of hypovolemic patients with determining collapsibility (>50%) of the IVC by bedside ultrasonography in conjunction with common clinical marker predictors, e.g., SI, MSI, and CVP.

Publication and Publisher Transfer Disclaimer: This article was originally published by WisdomGale Publishing, having its registered address at 14 Rue de Grand-Bigard, 1082 Brussels, Belgium. Following the formal transfer of publication rights and the subsequent change of publisher, the article was migrated to the publishing platform of International Medical Publishing Group (IMPG), India. The original publication details, authorship, and scholarly content remain unchanged. All subsequent publication management and archival responsibilities are administered by IMPG, India, in accordance with the terms and conditions of the publisher transfer agreement.

Downloads

Published

2026-11-01

Issue

Section

Articles

How to Cite

Validity of Shock Index, Modified Shock Index, Central Venous Pressure and Inferior Vena Cava Collapsibility Index in Evaluation of Intravascular Volume among Hypovolemic Egyptians Patients. (2026). American Journal of Diagnostic Imaging (AJDI) (ISSN: 2577-2058), 4(Issue 1), 5-13. https://internationalmedicalpublishing.com/index.php/AJDI/article/view/385